Bloc anti retour double piloté 1/2 BSP -R1:3.5 - 45 L/MN - 250 B - L 127
      Bloc anti retour double piloté 1/2 BSP -R1:3.5 - 45 L/MN - 250 B - L 127
      Bloc anti retour double piloté 1/2 BSP -R1:3.5 - 45 L/MN - 250 B - L 127
      Bloc anti retour double piloté 1/2 BSP -R1:3.5 - 45 L/MN - 250 B - L 127

      Bloc anti retour double piloté 1/2 BSP -R1:3.5 - 45 L/MN - 250 B - L 127

      Prix de base :
      144,05€ TTC
      Votre remise :
      20%
      Prix :
      €115.24 Tax Included
      96,03€ HT
      Stock
      2 articles disponibles
      Reference
      VT003008
      Poid : 0.84kg
      Délais
      Livraison : 1 à 5 jours

      Volume discounts

      QuantityUnit discountYou Save
      35%Up to €17.29
      1010%Up to €115.24
      2015%Up to €345.73
      5020%Up to €1,152.43
      10025%Up to €2,881.08
      Quantity :
      Prices according to quantity

      Volume discounts

      Quantity Unit discount You Save
      3 5% €17.29
      10 10% €115.24
      20 15% €345.73
      50 20% €1,152.43
      100 25% €2,881.08
      Weight 0.84kg
      Diamètres Int. des tuyaux en - pouce - millimètre - module
      Ø Int. en pouce Ø Int. en mm Ø Int. en module
      3/16 5 3
      1/4 6 4
      5/16 8 5
      3/8 10 6
      1/2 13 8
      5/8 16 10
      3/4 19 12
      1" 25 16
      1"1/4 32 20
      1"1/2 38 24
      2" 50 32

      1. VT003008
        BLOC ANTI RETOUR DOUBLE PILOTE
        RAPPORT : 1 : 3.5
        DN : 1/2 BSP
        DEBIT : 45 L/MN
        PRESSURE : 250 Bar

        A hydraulic circuit is an assembly of components necessary for the correct use of the installation, each with a very specific role. Whether they contribute to the safety of the installation or directly generate the expected mechanical work, these components cannot be neglected. From taps to in-line valves, not forgetting pressure gauges and other components all essential to the smooth running of your installation, we have selected the best quality to give you the opportunity to get your system up and running again without delay.

        To choose the right component, you need to refer to the part number of the faulty component, and if this is not possible, to the diagram or manual of the installation concerned. Never replace a part with a component that is unsuitable for the power rating of your installation. Doing so could endanger the operators in charge of running it, as well as its long-term future

      2. Hydraulic circuit

      Trale
      VT003008
      2 Items

      Data sheet

      Report
      1 of 3.5
      Non-return valve
      Double pilot operated - Block - VT003
      Operating pressure
      250 bar
      Female BSP thread
      1/2 BSP - 14F
      Flow rate in L/min
      45

      Specific References