Clapet anti retour simple piloté BLOC - DN 3/8 BSP - R 1:7 - 30 L/MN - 250 B
      Clapet anti retour simple piloté BLOC - DN 3/8 BSP - R 1:7 - 30 L/MN - 250 B
      Clapet anti retour simple piloté BLOC - DN 3/8 BSP - R 1:7 - 30 L/MN - 250 B
      Clapet anti retour simple piloté BLOC - DN 3/8 BSP - R 1:7 - 30 L/MN - 250 B

      Clapet anti retour simple piloté BLOC - DN 3/8 BSP - R 1:7 - 30 L/MN - 250 B

      Prix de base :
      90,90€ TTC
      Votre remise :
      20%
      Prix :
      €72.72 Tax Included
      60,60€ HT
      Stock
      2 articles disponibles
      Reference
      VT004006
      Poid : 0.49kg
      Délais
      Livraison : 1 à 5 jours

      Volume discounts

      QuantityUnit discountYou Save
      35%Up to €10.91
      1010%Up to €72.72
      2015%Up to €218.16
      5020%Up to €727.20
      10025%Up to €1,818.00
      Quantity :
      Prices according to quantity

      Volume discounts

      Quantity Unit discount You Save
      3 5% €10.91
      10 10% €72.72
      20 15% €218.16
      50 20% €727.20
      100 25% €1,818.00
      Weight 0.49kg
      Diamètres Int. des tuyaux en - pouce - millimètre - module
      Ø Int. en pouce Ø Int. en mm Ø Int. en module
      3/16 5 3
      1/4 6 4
      5/16 8 5
      3/8 10 6
      1/2 13 8
      5/8 16 10
      3/4 19 12
      1" 25 16
      1"1/4 32 20
      1"1/2 38 24
      2" 50 32

      1. VT004006
        BLOC ANTI RETOUR SIMPLE PILOTE
        RAPPORT : 1:7
        DN : 3/8 BSP
        DEBIT : 30 L/MN
        PRESSURE : 250 Bar


        A hydraulic system is a collection of components, each with a very specific role that is essential to the smooth running of the system as a whole. Whether they are involved in the safety of the system or directly in generating the expected mechanical work, these components cannot be neglected. From taps to pressure gauges, not forgetting in-line valves and other components all essential to the smooth running of your installation, we have selected the best to enable you to repair your circuit without delay.

        In order to select the right component, you need to rely on the part number of the faulty component or, failing that, on the information contained in the drawing or manual for the system in question. Never install a component that is incompatible with the power rating of your circuit. Doing so could endanger both the drivers and the system itself

      2. Hydraulic circuit

      Trale
      VT004006
      2 Items

      Data sheet

      Report
      1 of 7
      Non-return valve
      Single pilot operated - Block - VT004
      Operating pressure
      250 bar
      Female BSP thread
      3/8 BSP - 19F
      Flow rate in L/min
      30