Clapet Anti Retour piloté 3/8 FBSP - Rapport 1:6 -30 L/mn - 310 B
      Clapet Anti Retour piloté 3/8 FBSP - Rapport 1:6 -30 L/mn - 310 B
      Clapet Anti Retour piloté 3/8 FBSP - Rapport 1:6 -30 L/mn - 310 B
      Clapet Anti Retour piloté 3/8 FBSP - Rapport 1:6 -30 L/mn - 310 B

      Clapet Anti Retour piloté 3/8 FBSP - Rapport 1:6 -30 L/mn - 310 B

      Prix de base :
      71,41€ TTC
      Votre remise :
      20%
      Prix :
      €57.12 Tax Included
      47,60€ HT
      Stock
      2 articles disponibles
      Reference
      VT002006
      Poid : 0.9kg
      Délais
      Livraison : 1 à 5 jours

      Pilot operated hydraulic check valve F.F - 3/8 FBSP - 30 L/mn - 310 B - Ratio 1:6

      Volume discounts

      QuantityUnit discountYou Save
      35%Up to €8.57
      1010%Up to €57.12
      2015%Up to €171.37
      5020%Up to €571.25
      10025%Up to €1,428.12
      Quantity :
      Prices according to quantity
      (5/5) out of 1 total ratings
      Read the reviews

      Volume discounts

      Quantity Unit discount You Save
      3 5% €8.57
      10 10% €57.12
      20 15% €171.37
      50 20% €571.25
      100 25% €1,428.12
      Weight 0.9kg
      Diamètres Int. des tuyaux en - pouce - millimètre - module
      Ø Int. en pouce Ø Int. en mm Ø Int. en module
      3/16 5 3
      1/4 6 4
      5/16 8 5
      3/8 10 6
      1/2 13 8
      5/8 16 10
      3/4 19 12
      1" 25 16
      1"1/4 32 20
      1"1/2 38 24
      2" 50 32

      1. VT002006
        Type of valve
        Pilot operated check valve
        Installation (BSP)
        Female/Female 3/8
        Flow rate (L/min)
        30
        Working pressure (bar)
        310
        Pilot ratio
        1:6
        Pilot Ø (BSP)
        3/8

        3/8 BSP pilot-operated check valves - VT002006 are designed to prevent the return of fluid flowing in one direction only - from point A to point A1.In this case, the same functions are used as in the case of direct action, with the possibility of controlling the opening of the valve in direction A1 to A. A control orifice X is used through which fluid under pressure can be supplied to move a rod which unlocks the valve: the ball is pushed back from its seat to allow the fluid to pass through. The hydraulic system is made up of a number of components, each with a very specific role that is essential for the system to function properly. Whether they are involved in the safety of the installation or in the performance of the mechanical work itself, these parts cannot be neglected. From directional control valves to in-line valves, not forgetting pressure gauges and other hydraulic equipment, all of which are essential to the correct operation of the system, we have chosen the best quality/price ratio to give you the opportunity to get your system up and running again quickly.

        In order to select the right hydraulic components, you need to find your way around by looking at the part numbers of the component to be replaced, and if this is not possible, by looking at the instructions in the drawing or manual for the system concerned. Never install hydraulic components that are unsuitable for the power of your installation. Doing so could endanger the operators in charge of running the system, as well as the system itself.
      2. Non-return valve for hydraulic circuit.
      Trale
      VT002006
      2 Items

      Data sheet

      Report
      1 of 6
      Non-return valve
      Single pilot - VT002
      Operating pressure
      310 bar
      Female BSP thread
      3/8 BSP - 19F
      Flow rate in L/min
      30

      Specific References

      You might also like